01
Empty the chaff & water collector
Countertop
Twist off the collector
Twist the Chaff/Water Collector left to drop it out, pour the water into a drain, then invert it over a bin to dump the chaff. Lock it back by raising it in with the handle slightly left and rotating right.
Pull the lockbar outward and slide out the handled tray; empty the separate chaff and water bins, reinsert, push the tray back in and push the lockbar in.
Remove the two Prefilters from beneath the roasting drum, thoroughly vacuum both sides, and reinsert. (Every 3 roasts Countertop / 13 roasts Continuous.)
Push the two mesh pieces up out of the bracket (side nearest the handles), soak in coffee-machine cleaner (Cafiza, Joe Glo), air-dry, reassemble and refit.
Vacuum above the cooling tray & the cooling-brick ducts
Remove the Bean Cooler (Countertop) or the Valence/Autobucket (Continuous) and the Prefilters; vacuum inside the cooler and the area above it — especially the sealing surface and the ducts to the Cooling Bricks. Do not damage the Bean Cooler temperature probe (circled blue).
Towel in the water-collection cup, rotate the connecting ring left to disconnect, vacuum the tube bottom and top and up into the cyclone. Reassemble so the silicone is fully secured and the collar tight — no air leaks.
Bellwether’s inlet-screen article is members-only (login required), so its photos could not be downloaded. Sign in to your Bellwether account to view it.
Reseat the seals — chaff collector, chaff boot/collar, bean-cooler latch
Chaff collector: when correctly locked (Countertop) you should see a gap beneath it; on Continuous, if the seal doesn’t feel secure add a spacer under the chaff container. Chaff boot: fully reseat the silicone boot lip onto the Chaff Connector. Latches seal the collectors “to avoid any leaking of hot air, steam or gasses.”